Herunterladen Diese Seite drucken

Using E-Pak 500; Before Start-Up; Initial Start-Up; Checking The Direction Of Rotation - Nederman E-PAK 500 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für E-PAK 500:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
EN
E-PAK 500
Installation
Connect a compressed air supply to the inlet under the start and control unit, see Figure 5.
NOTE!
8

Using E-PAK 500

WARNING!
The unit creates a very strong vacuum.
WARNING!
Use ear protection.
8.1

Before start-up

The unit is tested before delivery and all functions are checked.
Before start-up, ensure that:
The maintenance switch is installed.
The installation room, if small, has ventilation openings. See
Section '7.1.1 Indoor installation'.
The plastic bag is in place in the collector bin.
NOTE!
The duct system is connected to the dust collector inlet.
The compressed air supply is permanently connected. Filter cleaning will not work
properly without a compressed air supply.
The PS cable is connected (if automatic start and stop is implemented), or that
terminals 3–4 in the start and control unit are linked by a jumper (if no PS cable is
connected).
8.2

Initial start-up

WARNING!
Work with electric equipment is to be carried out by a qualified electrician.
The initial start-up is to be performed with the acoustic enclosure removed to verify the
direction of rotation. Refit the acoustic enclosure when all checks have been performed.
NOTE!
8.2.1

Checking the direction of rotation

For the position of switches, see Figure 9.
To check the direction of rotation:
1.
Connect power by turning on the maintenance switch.
2.
Turn on the emergency switch below the control panel.
3.
Turn the standby and reset switch to position Reset.
4.
Turn the standby and reset switch to position 1 (standby).
NOTE!
button is pressed or a pilot signal is triggered, for example, by the opening of a valve at a
workstation.
28
Secure the compressed air line properly.
Risk of personal injuries.
Risk of impaired hearing.
Never run the unit without an plastic bag!
Risk of electric shock.
Ensure that no valves at any workstations are open.
If E-PAK 500 is connected to a PS cable, it will only start if the manual start

Werbung