External exhausting version
To utilize this function you have to provide with
a flexible duct Ø150 mm. to connect to the fitting
"F" (Diagram 2) , that must be subsequently fixed
to the ceiling.
Operation with recirculated air
When there is no exhaust duct for venting outdoors,
you can use a carbon filter. The air is depurated by
the filter and put again in the surrounding. To use
the appliance in this version, proceded as follows:
-
Fix the filtering fitting "D" to the bracket "E"
(Diagram 2).
-
Insert the ring "A" to the filtering fitting "D".
-
Insert a flexible duct from the fitting "F" to the
ring "A" and fix it with some small bands.
-
Open the grate;
-
Insert the filter "C" using the "B" knobs
(Diagram 6);
-
Remount the grate;
-
To convert the hood from "External exhausting
version" to "recirculated air," contact the
retailer or the manufacturer for the kit needed
for installation.

Installing the chimney

-
Fasten the "E" bracket (Diagram 2), located
on the perpendicular part of the outlet hole on the hood, at the highest point on the wall
next to the ceiling, using the two Ø 8 mm screws and wall anchors provided.
-
Make the chimney with slits run inside the other chimney
-
Fix the chimney with slits turned up to the bracket "E" using the two screws supplied with
the hood; put the other chimney on the upper part of the hood and fix it using the 2 screws
supplied with the hood.
Diagram 2
E
D
A
D.150
F
17