Herunterladen Inhalt Inhalt Diese Seite drucken

BWT AQA perla Bedienungsanleitung Seite 73

Duplex-weichwasseranlage
Vorschau ausblenden Andere Handbücher für AQA perla:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fault
01.07.14
10:45:21
AQA Stop triggered
For more info (Help button)
Press the question mark
Fault
01.07.14
10:45:21
AQA Stop Litre triggered
For more info (Help button)
Press the question mark
Fault
01.07.14
10:45:21
Drain 2 overflow
Service
The Service indicator appears after 500 regenera-
tions or 12 months, whichever is sooner.
You must contact BWT customer service to have
maintenance performed.
AQA Stop triggered
The floor sensor has detected water or continuously
flowing water has exceeded the amount specified.
Resolve the issue.
Dry the floor sensor if necessary.
H o l d d ow n t h e E n t e r bu t t o n fo r
5 seconds.
Alternatively, remove the mains plug, wait 10 sec-
onds and then plug back in.
The control valve will open again to let water
through.
Fault messages are indicated by a red screen and
a short description of the fault.
Acknowledge the fault
For example: Overflow fault
Acknowledge the fault
If a persistent problem arises, disconnect the mains
plug and turn the handwheel on the Multiblock mod-
ule to close it all the way (this opens the bypass for
the water supply).
Contact the after-sales service staff if the fault is
still displayed.