GB

Enclosed kit

Securing plate Part no: 020 095
Wall bracket Part no: 020 061
2 screws Part no: 016 193
for mounting
Cable harness between PKM and
FIGHTER 1140/1240
Part no: 009 182
Accessories
ROOM SENSOR RG 10
Part. no: 018 433

Technical specifications

Connection, hot side
Connection, cold side
Height (excl. pipe)
Width
Depth
Weight
Cooling output
Intended for heat pumps
18
2-pole variable relay with base
PKM 10
(mm)
22
(mm)
28
(mm)
515
(mm)
600
(mm)
370
(kg)
30
(kW)
2 – 5
(kW at 0/35 °C)
5 – 8
Part no: 418 867
Cable harness for the flow sensor from PKM
PKM 20
28
35
635
600
370
45
4 – 9
10 – 17
PKM
T-joint
Ø22 mm for PKM 10 Part no: 024 220
Ø28 mm for PKM 20 Part no: 024 210
to EBV-card on FIGHTER 1140/1240.
Part no: 009 181