Herunterladen Inhalt Inhalt Diese Seite drucken

Nibe PKM 10 Montageanweisung Seite 15

Vorschau ausblenden Andere Handbücher für PKM 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical installation FIGHTER 1140
The edge board connector should be cut from the en-
closed cable harness. The cable harness is then connec-
ted from the terminal block (-X200) in the distribution
box in PKM 10/20 to the terminal block -X6 in FIGHTER
1140 as follows:
The cable marked "1" is connected from -X200:1 to
-X6:20.
The cable marked "2" is connected from -X200:2 to
-X6:21.
The cable marked "3" is connected from -X200:3 to
-X6:22.
The cable marked "8" is connected from -X200:5 to
-X6:23.
The cable marked "6" is connected from -X200:6 to
-X6:16.
The cable marked "7" is connected from -X200:7 to
-X6:24.
Cables marked "4" and "5" are not used.
The yellow/green cable is connected between the free
earth stud in the heat pump and the earth terminal in
the distribution box.
Cable marking:
"1"
"2" "3"
PKM
29
1
If PKM is to be installed with FLM 40, the enclosed relay
must be connected. See section entitled "Connection of
relay in FLM 40".
"8"
"6"
"7"
PKM
32
8
GB
-X6
13

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pkm 20

Inhaltsverzeichnis