1. General
Before removing the terminal box module,
these fitting instructions should be studied
carefully. The installation and operation
should also be in accordance with local
regulations and accepted codes of good
practice.
Note: Pumps with modules must not be connected to
a frequency converter.
When fitted with a relay module, the pump can be
connected directly to a mains switch as it will be pro-
tected by the built-in overload protection at all three
speeds.
The relay module incorporates two indicator lights,
see fig. 1, and a signal output in the terminal block.
By means of a selector switch the signal output can
be set to activation during operation or fault, see fig.
1.
Fig. 1
Indicator lights
Selector switch
for signal output
The function of the two indicator lights and the signal
output is shown in the table in section 2.
4
2. Indicator lights and signal output
Signal output
Indicator Lights
activated
during
Oper-
Green
Red
Fault
ation
Off
Off
1
2
3
1
2
NC NO C
NC NO C
On
Off
1 2 3
1 2 3
NC NO C
NC NO C
On
On
1 2 3
1
2
NC NO C
NC NO C
Off
On
1
2
3
1
2
NC NO C
NC NO C
Flashes
Off
1 2 3
1
2
3
NC NO C
NC NO C
Flashes
On
1
2
3
1
2
NC NO C
NC NO C
Description
The pump has been
stopped. The elec-
tricity supply has
3
been switched off or
phase missing.
The pump is operat-
ing.
Three-phase
pumps only:
The pump is operat-
3
ing, but the direction
of rotation is wrong.
The pump has been
cut out by the ther-
3
mal overload switch.
The pump has been
stopped by an exter-
nal on/off switch.
The pump is or has
been cut out by the
thermal overload
switch and the exter-
3
nal on/off switch is
switched off.