Installation instructions, only for experts
4.2.

Installing the heater sensor F1 with excess temperature fuse

Observe the following points when installing the heater sensor:
● The heater sensor must be installed on the rear of the heater, above the mid-
dle of the sauna heater. An interval of approx. 15 cm to the roof of the sauna
room must be maintained.
● The heater sensor must be attached in a way that it is not affected by a fl ow
of air.
To install the heater sensor, perform the following steps (see Fig. 3):
1. Lay the two 2-pin heater sensor wires in the wall of the sauna room, leading
them to the heater sensor installation location and affi x the heater sensor
wires using wire clips.
2. Pull the two half-shells 1 of the heater sensor apart.
3. Connect the four connectors for the heater sensor wire 5 in accordance
with the Fig. 3.
4. Place the connection panel 2 crossways (as shown in Fig. 3) in the heater
sensor half-shells.
5. Place the two half-shells together, screw them together using the two Phillips-
head screws 3 (9 mm) and check whether the heater sensor has been
securely closed.
6. Install the heater sensor on the rear of the heater using the two wood screws
enclosed 6 (16 mm).
WORLD OF WELLNESS
Heater sensor half-shells
1
Connection panel
2
Phillips-head screws (9 mm)
3
Heater sensor
4
Heater sensor wires
5
Wood screws (16 mm)
6
Fig. 3 Installing the heater
sensor
p. 15/52