1. TECHNICAL DATA

TECHNICAL DATA
Height
Width
Depth
Weight
Weight with ceramic shell
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
Smallest heating capacity
Room heating capacity (depending on
building insulation)
2. IMPORTANT INFORMATION
The installation and operation information given here
. National and European
is of general nature
standards, local and building regulations as well as
fire prevention laws must be observed during the
operation of the stove.
General safety instructions for
the operation of your stove
Thoroughly read the entire manual before
starting up your stove and observe the caution
notices.
Your heating unit may not be moved without
approved means of transport with sufficient load-
bearing capacity.
Your heating unit is not suitable to be used as a
stand or as a ladder.
The burning of fuel releases thermal energy that
leads to a substantial heating up of the surface of the
heating unit, the doors and operating handles
mounted on the door, door glass, flue pipe and in
some cases the front wall of the heating unit. Do not
touch any of these surfaces without respective
protective clothing or without the help of accessories
such as heat-resistant gloves or a cold hand.
Make your children aware of this particular
danger and keep them at a distance from the heating
unit whenever it is in operation.
Only burn approved fuels and materials listed in
the chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like
into the firebox as well as the storage of such
materials in the immediate vicinity of your heating unit
is strictly forbidden due the danger of explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
4
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
709 mm
calculation of the chimney measurements in
690 mm
accordance with DIN 4705, Part 2
582 mm
Fluegas mass flow
160 kg
Fluegas temperature
-----------
150 mm
Minimum feed pressure
11 kW
Nominal thermal output
16 kW
5 kW
146 – 514
Placing non-heat-resistant objects on the
heating unit or in the vicinity of the heating unit is
forbidden.
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe
distance from the stove because of the danger of fire.
The woodstove Wien is not suitable for long term
heating.
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in
the same or an adjacent room to the one in which
your heating unit is located
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2))
a > 800 mm
b > 500 mm
c > 200 mm
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
Make sure that the room in which the stove is set
up has at least one door or window into the outside
or is directly adjacent to such a room. Other
fireplaces and extractor hoods must not be
operated in the same room as the stove.
english
closed
11,7 g/s
closed
265 °C
closed
12 Pa
at 0.8 times
10 Pa
n. ther. outp.
.