Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Kärcher GP 60 MOBILE CONTROL Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GP 60 MOBILE CONTROL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.997-340.0 Connection kit Pre-
mium G1(33.3 mm)
6.997-356.0 Swimmer switch
Danger
To avoid risks, all repairs and replacement of spare parts may only be carried out by au-
thorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.
Fault
Pump runs but does not
transport
Pump does not run or sud-
denly comes to a standstill
during operations
26
To connect 3/4" (25.4mm) water hoses to pumps
with G1 (33.3 mm) threaded connections. For in-
creased water flow.
Switches the pump on and off automatically de-
pending on the water level in the water tank. With
10 m special connection cable.
Note: In connection with GP 60 / GP 70 suitable as
a dry run protection, to switch off the pump in case
of water shortage.

Troubleshooting

Cause
Air in the pump
Suction pipe blocked
Pre-filter is dirty
Power supply interrupted
The additionally used swim-
mer switch has switched off
the pump.
Motor protection fuse
switched off the motor be-
cause of overheating
– 10
EN
Remedy
see chapter "Preparation"
fig. A and B and and chap-
ter "Operations" fig. C
Pull out the mains plug and
clean the suction pipe
Remove the pre-filter and
clean it under flowing wa-
ter; rinse out residual dirt, if
any, in the filter intake by
opening the drain.
Check fuses and electrical
connections
Restart the pump via the
remote control or the On/
Off switch if there is a suffi-
cient water supply.
Pull out the mains plug, let
the pump cool down, clean
the suction area, prevent
dry running