Fault
Pump switches on or off
unexpectedly
Pump transports is reduc-
ing or transported quantity
is too low
Our Kärcher branch will be pleased to help you further in the case of questions or faults. See
address on the reverse.
Cause
Program activated via remote
control
Remote control battery is
empty
Remote control range is ex-
ceeded or wireless signal of
the remote control is dis-
turbed due to wireless signals
of other devices
Suction pipe blocked
Pre-filter is dirty
Suction side is leaky
The quantity transported by
the pump depends on the
transport height and the con-
nected periphery
– 11
EN
Remedy
Check the remote control
settings
Change the battery
Reduce distance to the
pump. Maximum distance
to pump is 100m; walls and
other hindrances can re-
duce the range.
Pull out the mains plug and
clean the suction pipe
Remove the pre-filter and
clean it under flowing wa-
ter; rinse out residual dirt, if
any, in the filter intake by
opening the drain.
Check the entire suction
side for leaks
Keep max. flow height, see
technical data. If neces-
sary, select a different hose
diameter or hose length.