Herunterladen Diese Seite drucken

Safety; Description - Nederman 300E Series Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
3

Safety

WARNING!
For reasons of safety, this manual must be studied before
using the 300E for the first time.
• The 300E with 1 phase motor may only be connected to a grounded power
socket of the voltage stated on the machine data plate.
• Any damaged electrical component is immediately to be replaced with a
genuine spare part. Such work may only be performed by a person with the
necessary knowledge of electrical equipment.
• Any damaged component that is subjected to vacuum or overpressure is to
be replaced with a genuine spare part to avoid the risk of spreading harmful
dust.
• It is prohibited to lift the 300E by the handle on top of the power unit or to
be underneath the 300E while it is being lifted by the frame handle. See
Chapter '9 Transport and lifting'.
• The safety guard must not be removed as there is risk of injury to fingers if
the top of the motor is removed and the unit is started.
• Hot or red-hot material, flammable fluids, explosive or health-impairing
fumes as well as dust that could cause an explosion may not be sucked into
the unit. Neither may the unit be used in spaces where such material exists.
• For reasons of safety, do not put the vacuum hose inlet near the eyes, ears or
other part of the body.
• Anti-static vacuum hoses, hose fittings and filters is to be used in order to
reduce the danger of sparks and dust explosions.
• The 300E with 1-phase motor has a noise level of 75 dB(A) when in normal
operation. Use approved ear defenders during longer periods of use.
• Unplug (unit with a 1 phase motor) the power supply before removing the
motor assembly from the unit. Take care not to spread dust when changing
the plastic sack or bag and when replacing the micro-filter.
• Wear an approved breathing mask in the case of hazardous dust.
• Do not operate the unit with a 1 phase motor when the vacuum is almost or
fully restricted. or no airflow, since this could result in overheating of the
fan motors.
• The 300E is not classified as a wet vacuum cleaner. Large amounts of water
may not be sucked into the unit. However, it may be used for damp material
and in a damp environment.
4

Description

300E is an industrial vacuum cleaner. Electrical driven, 1-phase with
separately cooled motors. The unit is provided with manual and automatic
start/stop modes. In the automatic start/stop mode, the unit is controlled by a
connected electric or pneumatic tool (the 110–120 V version for a pneumatic
tool only).
The rated power, voltage, safety class, flow, working pressure, max pressure
and so on are stated on the machine data plate, see Figure 14. The noise level
during normal operation is 75 dB(A) according to ISO 11201.
300E Series
EN
11

Werbung

loading