Supplement 1
If you want to activate a function enter the value to the corresponding output according to the following
table. In case you want to activate several functions simultaneously you must add up their specific values.
Output's values:
RG
Value
128
RG = Shunting gear ABL = dimmed headlights
Example:
F4 should activate the shunting gear and switch on the outputs LV and LR:
LV=1, LR=2, RG=128: so you must enter the value 131 in CV38 | par66.
Notice:
AUX3 and AUX4 are not available in the decoder DH05C and DH10C.
Timer function
(CV117 - 120, par076 - 079)
Value = 0
The timer is switched off (permanent function)
Value = 1...250
The timer is activated, the correspondent output will be disconnected after the set time
of: entered value x 0.1 sec.
Explanation for function mapping
ABL
AUX4
64
32
AUX3
AUX2
16
8
38
AUX1
LR
4
2
LV
1