Herunterladen Inhalt Inhalt Diese Seite drucken

Setup Features - D&H DH05C Anleitung

Vorschau ausblenden Andere Handbücher für DH05C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.2

Setup Features

The characteristics of a locomotive operated in the DCC-operating mode can be varied by programming the
configuration variables (CV) freely at any time. The programming procedure is described in the instructions
of your programming device.
Notice:
In case the speed steps programmed on the decoder differ from those of the control device,
malfunctions may occur. Please pay attention to the respective information concerning your digital
system.
List of supported CV:
CV
Name and definition
01
Short address
02
Starting voltage
03
Acceleration time
The value corresponds to the time in seconds from start to maximum speed
04
Deceleration time
The value corresponds to the time in seconds from maximum speed to stop
05
Maximum speed
07
Version number
08
Manufacturer identification
97 = Doehler & Haass (Decoder Reset with "8")
09
Motor frequency
0 = 32 kHz, 1 = 16 kHz, 2 = low-frequency
(See supplement 2)
(Read only)
(Read only)
18
Range
0 – 127
(3)
0 – 15
(0)
0 – 255
(3)
0 – 255
(3)
0 – 127
(92)
0 – 2
(1)