UK │ 4. Safety instructions and warnings
Exercise caution when handling
packaging materials.
 Observe applicable safety and accident
prevention requirements.
 Store packaging material out of the reach
of children (risk of suffocation).

5. Operation

Fan and swivel drive are switched on and off
separately via a switch.
Special accessories with time-delayed
switching or humidity function can be used.
In the event of thermal overload, the fan
switches off. Wait until the motor has cooled
down. Cool-down time can take
up to 10 minutes. Unit switches back on
automatically after cooling down.
6. Environmental conditions and
operating limits
● Permitted ambient and airstream
temperature + 40°C.
● Information for operation with occasional
temperatures below -20° on request.

7. Technical data

Rated voltage
Power frequency
Power consumption
I
max
Sound pressure level
Degree of protection
Weight
For more technical data,  rating plate.
For dimensions  Fig. C.
14
230 VAC
50 Hz
ECO 30 E: 37 W
ECO 40 D: 44 W
0.25 A
ECO 30 E: 57 dB(A
ECO 40 D: 65 dB(A)
IP 20
ECO 30 E: 3.1 kg
ECO 40 D: 4 kg

8. Transport

NOTICE:
Unit damage in case of incorrect
transport if the fan unit slips out of the
rotary axes.
The fan unit is inserted in both of the
bushings/rotary axes and is not secured.
Therefore, hold the fan by the protective
cage when removing it from the transport
box and transport it.

9. Storage

Store unit exclusively in a dry location
(-20 to +50 °C).

10. Mounting information

● Installation only permissible on even, solid
walls with sufficient load-bearing capacity
(min. 200 kg/m³).
● Make sure there is sufficient space
between the fan unit and the wall and
ceiling.
● Can be installed in any position on the
wall.
● Swivel axis should preferably be
horizontal. For other swivel directions,
feed the power cable through from the
bottom if possible.
● Select installation site so that foreign
bodies will not be accidentally drawn in.
Observe installation height.
● Take the risk of draughts into account
when planning by selecting a suitable
installation location.
● To avoid sound bridges with the structure,
observe distances from other façade
components and, if necessary, use
isolating elements.
● Mounting material that is sufficiently
dimensioned and suitable for the surface
is to be supplied by the customer.