Commissioning
Test automatic for light sensor
This function serves for a fast test of the light sensor. Here
the delay time set in minutes is converted into seconds
(see also chapter "Programming of times").
Starting the test automatic
If necessary, change into automatic mode with button
<Auto>.
To move the awning to its fully retracted position press
button
top) appears in the display.
Press the buttons <Space> and <Auto> simultaneously
for approx. 1 second. The activation is displayed with a
flashing symbol "ESO".
If the symbol does not flash the light sensor and
connections must be checked.
Deactivating the test automatic
The function is switched off automatically when the awning
has been fully retracted and the symbol "ESO" stops
flashing after the set pulse duration.