Commissioning
19
Commissioning
Checking direction of travel
After completing the installation proceed as follows with
the start-up:
Switch on the mains supply.
Press the button <Auto> repeatedly until operating
mode "Manual" appears in the display.
Press the button
direction of travel.
If the awning's direction of travel does not
correspond to the symbols
of the motor connection have been reversed (see
fig 4).
Switch off the mains supply and correct the
connection in accordance with chapter
"Installation".
or
, to check the awning's
ENG
or
, the terminals
75