Herunterladen Inhalt Inhalt Diese Seite drucken

Installing The Service Door; Create Wall Apertures; Wall Aperture Service Door; Wall Aperture Flap - Dometic CT 4110 Einbauanleitung

Vorschau ausblenden Andere Handbücher für CT 4110:
Inhaltsverzeichnis

Werbung

Installing the toilet

4.0 Installing the toilet
4.1

Installing the service door

The description for the installation of the ser-
vice door can be found in the document sup-
plied
Dometic
Seitz
(optional/depending on model).
4.2

Create wall apertures

4.2.1 Wall aperture service door

Make an aperture in the wall for the cassette
with the following dimensions:
for service door SK4
y = 25 mm ; b = 305 mm and h = 375 mm ,
for service door SK5
y
min
= 12.5 mm and y
max
and h = 360 mm.
The x value results from the toilet installation.
Observe the position of the service door (tem-
plate (3) and (4), Item 5.3.1.).
b
SK 4
b
SK 5
SK4,
SK
5
= 28 mm; b = 310 mm
h
y
Fig. 4
h
y
Fig. 5

4.2.2 Wall aperture flap

The flap is applied when using CTW 4xxx
models with an integrated water tank. Use the
template (1) , Item 5.3.1., to make the apertu-
)
re for the flap. You can find the installation
instructions for the flap under Item 4.5.
4.3
Installing the toilet
CAUTION!
All components of the system must be
installed in frost-protected areas. In minus
temperatures there is a risk of damage
due to frost.
Install the toilet according to the description of
the respective model. Allow sufficient space
so as not to limit the operation of the empty-
ing valve.
Install the toilet against an upright wall only.
When installing the toilet in a wet room, we
recommend connecting the toilet with the
shower tub. The toilet pedestal is fitted with a
projecting flange in order to cover the top rim
of the shower tub.
24
Fig. 6

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis