Basic unit for 2 insertion modules
These instructions are intended for technicians
installing the unit . Please read the instructions
carefully prior to operation and keep them for
later reference .
1
Overview
1 Cover panel for the insertion compartment 1
2 Cover panel for the insertion compartment 2
3 POWER LED
4 POWER switch
5 Mains jack for operation with 230 V/ 50 Hz
6 Mains fuse
Only replace a blown fuse by one of the same
type .
7 Cover plate 2
8 Screw terminals for a 24 V emergency power
supply
9 Master output "1 + 2"
10 Output PACK 2 of the insertion 2
11 Output PACK 1 of the insertion 1
12 Cover plate 1
2

Safety Notes

The unit corresponds to all relevant directives of
the EU and is therefore marked with
WARNING The unit is supplied with hazard-
ous mains voltage . Leave servicing
to skilled personnel only . Inexpert
handling or modification of the
unit may cause an electric shock
hazard .
The unit is suitable for indoor use only . Protect
it against dripping water and splash water, high
6
PA-1200EX
1
air humidity and heat (admissible ambient tem-
perature range 0 – 40 °C) .
Do not place any vessels filled with liquid, e . g .
drinking glasses, on the unit .
Do not set the unit into operation and immedi-
ately disconnect the mains plug from the mains
socket if
1 . there is visible damage to the unit or to the
mains cable,
2 . a defect might have occurred after a drop
or similar accident,
3 . malfunctions occur .
The unit must in any case be repaired by skilled
personnel .
Never pull the mains cable to disconnect the
mains plug from the mains socket, always seize
the plug .
For cleaning only use a dry, soft cloth; never
use chemicals or water .
No guarantee claims for the unit and no liability
for any resulting personal damage or material
damage will be accepted if the unit is used for
other purposes than originally intended, if it is
not correctly connected or operated, or if it is
not repaired in an expert way .
If the unit is to be put out of operation
definitively, take it to a local recycling
plant for a disposal which is not harmful
to the environment .
.
3
Applications
The unit has especially been designed to accept
two of the following insertions from MONACOR:
PA-1120DMT digital message storage with timer
PA-1140RCD
PA-1200C
PA-1200RDSU AM / FM radio
2
3
ON
POWER
radio / CD player
timer
4