The limit switch of the drive is automatically actuated when the window is being closed.
The machine applies a pull force which is greater than 550 N and ensures that the window
seals close properly, even when using large-sized closing fi xtures.
7.2 Installation of drive, rack and pinion follower and connecting rod
Drive and rack and pinion follower can be installed in a row when using heavy and/or wide
sashes. A rack and pinion follower can provide an additional opening/locking point. The drive
and the rack and pinion follower are synchronised by means of a mechanical connecting rod.
The following drawing shows the arrangement and centre-to-centre distances that must be
observed during installation.
Tandem with 1 motor and 1 rack and pinion follower
ATTENTION
Tandem use of
2 drives is
not possible!
Centre-to-centre distances of connecting rods
Description
Connecting rod 1000 mm
Connecting rod 1500 mm
Connecting rod 2000 mm
Connecting rod 2500 mm
Mark the centre-to-centre distance D on the closing fi xture for
installation of the drive and the rack and pinion follower.
For the defi nitive dimensions, refer to the above table.
Position the mounting bracket of the drive, mark the positions
of the holes, drill hole in closing fi xture and attach the bracket
(see explanation in the section "Installation").
08.2014 | G27959 | Printed in Germany
fi g. 4
Rod length
1035 mm
1535 mm
2035 mm
2535 mm
fi g. 5
D
Centre-to-centre distance, drives D
1000 mm
1500 mm
2000 mm
2500 mm
fi g. 5b
fi g. 6
23