Fault
The interior cleaner does
not turn or only turn partial-
ly or abruptly
Uneven cleaning jet

Accessories

Description
Parts kit for frame
Cover with frame
Swivel frame
High-pressure connection
bow 90°, M22x1.5
Regulator fluid for normal
operation - cold/warm run
0.25 liters
Regulator fluid for normal
operation - cold run 0.25
liters
Regulator fluid for food op-
erations - cold run 0.25 lit-
ers
Regulator fluid for food op-
erations - cold run 1 liters
Regulator fluid for solvent
operations - cold run 1 liter
26
English
Possible cause
The speed is set too low.
The pressure of the cleaning
agent is too low or the wrong noz-
zles have been installed on the in-
terior cleaner.
Air in the reguator fluid.
Wrong regulator fluid has been
used.
The seals on the shafts are leak-
ing.
Bevel wheels dirty.
Spray nozzles clogged.
Spray nozzles damaged.
We hereby declare that the machine de-
scribed below complies with the relevant
Order No.
basic safety and health requirements of the
on request
EU Directives, both in its basic design and
construction as well as in the version put
on request
into circulation by us. This declaration shall
on request
cease to be valid if the machine is modified
without our prior approval.
4.408-023
Product:
Type:
6.288-021
Relevant EU Directives
98/37/EC (to 28.12.2009)
2006/42/EC (from 29.12.2009)
4.070-020
94/9/EC
Applied harmonized standards
EN ISO 12100–1
EN ISO 12100–2
4.070-033
EN 1127-1: 1997
EN 13463-1: 2002
EN 13463-5: 2003
4.070-047
Applied national standards
-
ID no. of notified body
6.288-007
0123
TÜV SÜD
Ridlerstr. 65
80339 München
Test report no.
Ex5 0307 10088 097
Marking
II 1 G D c T4
5.957-455
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
CEO
Alfred Kärcher GmbH Co. KG
Troubleshooting
Remedy
Adjust higher speed on the regulator screw.
Adjust the nozzles on the interior cleaner to the
feed flow of the high-pressure pump (smaller
nozzle opening means higher pressure).
Replace regulator fluid (see Maintenance Pro-
cedures).
Replace the regulator fluid completely.
Replace washers.
Clean bevel wheels (see Maintenance Proce-
dures).
Clean spray nozzles.
Replace spray nozzles.

CE declaration

Internal cleaner
HKS 100
Head of Approbation
of whom
Operator
Operator
Operator
Customer Service
Customer Service
Operator
Operator
Operator
Alfred-Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212

Warranty

The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of the appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication.
In the event of a warranty claim please con-
tact your dealer or the nearest authorized
Customer Service centre. Please submit
the appliance, including all accessories,
and the proof of purchase.

Werbung