Herunterladen Diese Seite drucken

Kärcher BRS 40/550 C CARPET Betriebsanleitung Seite 17

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating Instructions
! Remove the rotary brushes from
the gearing
! Place the brush roller on its drive
side (gearing)
! Dismantle the second rotary
brush as described
! Position the cleaner vertically
Transport
Note:
Moving it on its castors indoors and
on smooth floors is not a problem.
Take care when moving on non-
smooth floors and in outside areas.
! Push the unit on its castors
Warning!
Danger of injuries caused by a unit
falling off
BRS 40/550 C CARPET
Cleaning and maintenance
! Only use a damp cloth for
cleaning the cleaner
! Wipe afterwards with a clean, dry
cloth
! Do not use chemical cleaning
agents
Frost protection
! Store the cleaner in a room
protected from freezing
Recommended cleaning
agents
Cleaning carpeting
Powerful carpet-cleaning detergent
RM 770
Carpet-cleaning granules
RM 771
Cleaning elastic and hard
floor coverings (option)
Cleaning greasy dirt deposits
RM 69 ASF
6.291-523
Maintenance cleaning
RM 746
6.291-462
Accessories
BRS 40/550 C CARPET
accessories
Brush roller (green)
For velvet-pile carpets
The unit requires 2
1 only
4.762-000
Rotary broom (light blue)
For a loop pile carpet
The unit requires 2
1 only
4.762-254
Scrubbing accessories for
hard and elastic floor
coverings
Rotary brush (red)
For maintenance cleaning
The unit requires 2
1 only
4.762-249
Rotary brush (orange)
high/low, for structured floors
The unit requires 2
1 only
4.762-251
Rotary brush (white)
soft, for polishing
1 only
4.762-250
Power cable *EU
20 m
6.647-022
English
Fault instructions
Unsatisfactory cleaning results
! Replace worn rotary brooms
! Check detergent dosage
Rotary brushes do not turn
! Remove jammed foreign bodies
! The appliance is overloaded, the
overcurrent protection switch
triggered, allow it to cool down.
The appliance is operable again
after approx. 30 s.
! Use rotary brushes suitable for
job
Mains circuit breaker triggers
when the cleaner is switched on
! Make sure mains fusing (16 A
slow blow) is adequate
! Switch off other consumers or
use other power circuit
Cleaner runs unevenly or vibrates
heavily
! Check the proper fit of the rotary
brooms
! Exchange the right for the left
hand rotary broom and vice versa
! Soak the rotary brooms in hot
water (approx. 80°C) for
approx. 15 min.
The unit must be checked by after
sales service if the problem
cannot be remedied.
17