Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation - ABB ACSM1-04 Serie Kurzanleitung

Vorschau ausblenden Andere Handbücher für ACSM1-04 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
4
it is however highly recommended to fasten
these modules to the mounting base also by
two screws through the lower mounting holes.
For installation of the cold plate drive modules
(ACSM1-04Cx-xxxx-x), follow the instructions
in the ACSM1-04 Drive Modules (0.75 to 45
kW) Hardware Manual.

Electrical installation

Supply disconnecting
device (disconnecting
means) with fuses
CHK-xx mains choke
(optional)
JFI-xx mains filter
(optional)
ACSM1-04
UDC+ UDC–
U2 V2 W2
V1
U1
W1
3~
Motor
*Note: For motor cabling, use a separate
ground cable if the conductivity of the motor
cable shield is less than 50% of that of a phase
conductor and the cable has no symmetrical
ground conductors.
Power cabling procedure
Cabling examples are presented on page 5.
Tightening torques are presented on page
and at appropriate points in the text.
• Attach the terminal blocks included to the
drive.
Quick installation guide - ACSM1-04
L1 L2 L3
PE
U
V
W
PE
X
Y
Z
L1
L2
L3
L1'
L2'
L3'
U1 V1 W1
PE
R–
R+
*
Braking resistor
PE
(optional)
5
• ACSM1-04xx-024A...090A-4 only: Remove
the two plastic connector covers at the top
and bottom of the drive. Each cover is held
by two screws.
• On IT (ungrounded) systems and corner-
grounded TN systems, remove the screw
labelled VAR located close to the supply
terminals.
• Fasten the two cable clamp plates included
to the drive, one at the top, one at the
bottom. The clamp plates are identical.
• Strip the power cables so that the shields are
bare at the cable clamps.
• Connect the supply, resistor (if present) and
motor cables to the appropriate terminals of
the drive.
• Tighten the cable clamps onto the bare cable
shields. Connect the ends of the cable
shields to the ground terminals using cable
lugs. Cover visible bare shield with insulating
tape.
• ACSM1-04xx-024A...090A-4 only: Cut
suitable slots on the edges of the connector
covers to accommodate the cables. Refit the
covers.
• Ground the motor cable shield at the motor
end.
ACSM1-04xx-02A5...016A-4:
1.5 N·m (13 lbf·in)
ACSM1-04xx-024A...090A-4:
3 N·m (25 lbf·in)
1.5 N·m
(13 lbf·in)