• All stainless steel components can be cleaned using a conventional detergent. Abrasive agents and spon-
ges/brushes that cause scratching are not suitable. Ideally use a pipe cleaner thread to clean the bottom
element part.
• When cleaning the brewing vessel ensure that no water spray or moisture comes into contact with the elec-
trical components. The Plug must be disconnected for performing cleaning activities.
• Before starting the brewing process, remove all dust and dirt from the device and all internal fittings by
means of warm water.
• The valve also needs to be cleaned, all the components like water pipe, cover and false bottom should be
cleaned, as this could have a negative impact your brewing results.
Problem
Element with burn marks.
Switches off during boiling.
E1 shown on display.
Machine fails to switch on.

Disposal and Declaration of Conformity

According to the European waste regulation 2012/19/EU this symbol on the product
or on its packaging indicates that this product may not be treated as household waste.
Instead it should be taken to the appropriate collection point for the recycling of electrical
and electronic equipment. By ensuring this product is disposed of correctly, you will help
prevent potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of this product. For more de-
tailled information about recycling of this product, please contact your local council or your
household waste disposial service.
Producer: Chal-Tec GmbH, Wallstraße 16, 10179 Berlin, Germany.
This product is conform to the following European Directives:
2014/30/EU (EMC)
2014/35/EU (LVD)
2011/65/EU (RoHS)
9

Troubleshooting

Possible Cause and Solution
Use an ingredient bag during mashing.
Clean it with vinegar, Lemon juice and a soft cloth.
Do not use 2500W for full power boiling, switch it to 1600W.
Contact seller change a higher temperature limited thermostat.
Sensor is not connect to PC board properly, please open the underneath
and re-insert it again.
Please use a current meter to check the fuse.
If the fuse is broken, please contact seller for a new fuse supply.
Please use a current meter to check the switch current.
If the switch is broken, please contact seller for a new switch supply.