The transition between the power circuit for the Central Station and
the power circuits for the Boosters must also have a rocker insulator
installed in it (H0).
The Central Station may not be connected directly to the track when
using Boosters with 1 Gauge (exception: separate programming track).

10. Additional Notes:

Please note the following additional special features about this
version of the Central Station:
1. You may have function problems with the first generation of 763xx
series color light signals with their integrated decoders. Ask your
authorized digital dealer about the procedure for updating the old
signals for the new ones.
2. The 7686 digital turntable is (still) not supported with its own
control area.
3. It is not possible to take a locomotive on a layout from Märklin
Systems to another operating system. Catenary is not to be used
with Märklin Systems to power locomotives and powered units.
Caution! The Central Station will suffer damages if it is connected
electrically to other operating systems!
4. Do you have ideas or wishes about future versions of the
Central Station?
You can let us know about this easily at the Internet address
"www.maerklin-systems.de". Please understand that this possi-
bility for making entries is only for gathering customer reaction.
You will therefore not receive a reply to your comments in this
entry field. In future versions of the Central Station you may
possibly see your information translated into new features. If you
require technical help, please contact us at this e-mail address:
"digitalfragen@maerklin.de"
5. Please make sure that you have made the connections in the right
sequence! We are referring here to the sequence described in this
instruction manual. Don't confuse the cable connection for the
layout with the connection for the programming track.
6. We recommend that you connect turnouts and signals with more
than one mechanism (example: three-way turnout, 7041 and 7241
multiple aspect signals) to a k83 decoder, because you will have a
better overview of the connections!
7. This also applies to the address procedure for single turnout
decoders (6073 or 74460). The two single decoders must have
the same basic decoder address. Switches 1 to 8 on the decoder
must be identical! Switches 9 and 10 (0) indicate the individual
output for the turnout in question.
Gebr. Märklin & Cie. GmbH
Postfach 8 60
D-73008 Göppingen
www.maerklin.com
Central Station mit Update 60212
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.