Do NOT put the uppermost glass of the tower into
the dishwasher. This may cause scratches in the
glass; it may also damage the coating on the base.
Wipe the surface with a damp cloth. (the same is
true for the hob glass).
Turn the glass a quarter of a turn to the right to be able to
remove the glass from the tower. Slide the 2 slats on the side of
the tower upwards. You will see the 2 metal grease filters inside
the tower.
The filter can be cleaned as follows:
– In the dishwasher
– By hand: Immerse the filter in a mixture of boiling water and
grease-cutting dishwashing liquid. Use warm water to rinse
the filter under the tap, then leave it to dry.
WARNING: If the instructions described above are
not followed, residue in the filter may cause a fire.
After cleaning:
– Place the filters and the glass back onto the tower.
– Place the tower back into the opening.
– Press the
key for three seconds.
9.4 Cleaning the Monoblock recirculation
filter (only with recirculation)
If recirculation has been selected, the device has been
connected to an built-in recirculation box with a Monoblock
recirculation filter.
Regenerating the Monoblock recirculation filter:
– The Monoblock can be regenerated up to 12 times. This is
done in the oven.
– Place the filter in the oven for 1 hour at 120°C. Provide
sufficient fresh air in the room where the oven has been
placed, as smells can be released. Smells can be released
when baking certain kinds of fish. The best solution for this is
to immediately regenerate the filter.
After cleaning:
– Return the Monoblock recirculation filter into the built-in
exhaust box.
– Press the control key
10 TROUBLESHOOTING MINOR
FAULTS
10.1 Messages on the hob
Code
– there is no cooking pan on the cooking zone
– the cooking pan is not suitable for induction
– the diameter of the bottom of the cooking pan
is too small when compared to the cooking
zone
See Chapter 4.3.9 Keep warm
U
– The electronic system is disrupted.
– Disconnect and reconnect the hob.
E
– Call the after-sales service
See Chapter 4.3.7 Stop & Go
I I
The controller keys are covered by liquid or an
item. The symbol will disappear as soon as the
(Er03)
keys are released or cleaned.
The hob has overheated, leave to cool, then
E2
switch back on.
The fan air supply is blocked.
E8
Unblock it.
The hob has not been properly connected to the
U400
network. Check the connection.
(Er47)
Problem in the device's internal bus system.
If one of these error messages remains visible, you can contact
the after-sales service.
– 70 –
for 3 seconds.