Herunterladen Inhalt Inhalt Diese Seite drucken

Remote Control; Function Modes - Cardin BLi924ESB Anleitung

Integrierte drehtorantriebe 24vdc
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28

REMOTE CONTROL

The system can be remotely activated using radio control devices; to set the two
functions to channels A-B-C-D use the selection jumper "J4":
- in position "A" function 1 is selected, SEQUENTIAL COMMAND;
- in position "B" function 2 is selected, CH2 (binding posts 9, 10) only if "J5" is in
position 2.
The sequential command may be set (dip "1") to:
"open-block-close-block" or "open-close".
Memory module (MM)
This is extractable, furnished with a non volatile EEPROM type memory and contains
the transmitter codes and allows you to memorise up to 300 codes. The programmed
codes are maintained in this module even during blackouts.
Before memorising the transmitters for the first time remember to cancel
the entire memory content. If the electronic card has to be replaced due
to failure, the module can be extracted from it and inserted into the new
card. Make sure that the module is correctly inserted as shown on fig. 2.
Signal LED "L4"
Flashing quickly:
cancels a single code
Flashing slowly:
memorises a single code
Permanently lit:
memory full.
TRANSMITTER CODE MANAGEMENT
Memorising a channel
1. Press and hold down button "P2" MEMO: The LED "L4" will flash slowly.
2. At the same time activate the transmitter which is to be memorised.
3. Hold down button "P2" MEMO until LED "L4" starts to flash again.
4. Release the MEMO button: The LED will continue to flash.
5. Activate the transmitter again (same transmitter, same channel; if the channel is
different or it is a different transmitter the memorisation attempt will abort without
success).
6. End of memorisation: the LED "L4" will remain lit for 2 seconds, indicating that the
transmitter has been correctly memorised.
Notes: It is not possible to memorise a code which is already in memory: if you
attempt this, the LED will switch off when you activate the transmitter (point 2). Only
after releasing the button "P2" MEMO will you be able to continue the memorising
procedure. If after activating the transmitter for the first time you wait for more than
fifteen seconds without activating the transmitter a second time the memorisation
attempt will abort without success.
Cancelling a channel
1. Press and hold down the button "P3" DEL: the LED "L4" will flash quickly.
2. Activate the transmitter channel that is to be cancelled.
3. The LED will remain lit for 2 seconds, indicating that the transmitter has been can-
celled.
Notes: If the user that you wish to cancel is not in memory, the LED will stop flash-
ing; only after releasing the button "P3" will you be able to continue the cancellation
procedure. For both the memorisation and cancellation procedures, if the button is
released before activating the transmitter the procedure will abort.
Cancelling all user codes from memory
1. Keep both buttons pressed down ("P2+P3") for more than four seconds.
2. LED "L4" will remain lit during the entire cancellation time (about 8 seconds).
3. LED "L4" switches off when the cancellation procedure has terminated.
Note: When the memory is almost full the time required to search for a user code could
take up to 1 second from when the command was received. If LED "L4" remains lit
memory is completely full. To memorise a new transmitter you will first have to cancel
a code from memory.
Memorising ulterior channels via radio
• Memorisation can be activated by radio (without opening the receiver container) if
jumper "J3" has been inserted (fig. 2).
1. Make sure that the jumper "J3" has been inserted (fig. 2).
2. Using a transmitter, in which at least one channel button "A, B, C or D" has already
been memorised in the receiver, press the button in the transmitter as shown in
figure.
Note: all the receivers within range when the channel button is pressed (and which
have at least one of the transmitter channel buttons memorised) will activate their
signal buzzer "B1" (fig. 2).
3. Press one of the channel buttons on the same
transmitter. The receivers which do not contain
that channel code will sound a five-second long
"beep" and will then deactivate. The receivers which
contain the channel code will sound a one-second
long "beep" and will enter the "programming via
radio" mode.
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
4. Press the previously chosen channel buttons on the transmitter which you wish to
memorise; the receiver will sound 2 "beeps" of half a second each after which the
receiver will be ready to receive another code.
5. To leave the programming mode wait for 3 seconds without pressing any buttons.
The receiver will sound a five-second long "beep" and will then exit the programming
mode.
Note: When the memory is entirely occupied the buzzer will sound 10 rapid "beeps"
and will automatically leave the "programming via radio" mode. LED "L4" will remain
lit on the receiver. The same signal is given each time you try to enter "programming
via radio" when the memory is full.
CONNECTING THE ANTENNA
Connect an ANS400 tuned antenna using a coaxial cable RG58 (impedance 50Ω) with
a maximum length of 15 m.

FUNCTION MODES

1) Automatic
Selected by enabling automatic reclosing (dip "2" in position "ON"). When the door is
completely closed the opening command will start a complete cycle which will end with
automatic reclosing. Automatic reclosing starts after the programmed pause period
has elapsed when the opening cycle has been completed or straight away after the
intervention of a photoelectric cell (the intervention of a photoelectric cell causes the
pause time to be reset). During the pause time the symbol
and pressing the blocking button during this period will stop automatic reclosing and
consequently stop the display from flashing. The indicator light remains lit until the
closing manoeuvre has terminated.
Note: the courtesy light switches on each time a movement command is given (both
via cable or via radio) and switches off 30 seconds after the manoeuvre has been
completed (only if jumper "J5" is in position "1", fig. 2).
2) Semiautomatic
Selected by deactivating automatic reclosing (dip "2" in position "OFF"). Work cycle
control using separate opening and closing commands. When the door has reached
the completely open position the system will wait until it receives a closing command
either via an external control button or via radio control, before completing the cycle.
The indicator light remains lit until the closing manoeuvre has terminated.
3) Manual manoeuvring with released motors
Releasing the motor the gate can be moved by hand; in this stage the programmer
controls the position of the gate leaves.
4) Emergency manoeuvre
If the electronic programmer no longer responds to commands due to a malfunction
you may use the EMRG1 or EMRG2 inputs to move gate leaf 1 manually. The EMRG1
and EMRG2 inputs directly command the motor relays without passing through the
logic control. Gate movement will be at reduced speed and the direction depends on
the installed position of the motor (left or right). The voltage at motor binding posts 1
and 2 has the following polarity:
Command EMRG1: binding post 1 (+) binding post 2 (-)
Command EMRG2: binding post 1 (-) binding post 2 (+)
Attention! During the emergency manoeuvre all safety devices are
disabled and there is no gate positioning control: release the commands
before you are at the mechanical travel buffer. Only use the emergency
manoeuvre in cases of extreme necessity. The electric lock (even if it is
enabled) is not active. Therefore if an electric lock is fitted it will have to
be activated manually.
After you have carried out an emergency manoeuvre the electronic programmer will
lose the position of the gate leaf (
operation is restored it will carry out a repositioning manoeuvre when a command is
given (see page 15).
LIMITED OPENING
This always effects gate 1; the limited opening space can be set (see display menu) to
1/3, half, 2/3 or the entire opening distance for gate 1. The command can only be car-
ried out with both gates completely closed; if dip 1 is set to "OFF" and during opening
you activate the "TAL" command again gate leaf 1 will block and when it receives the
next command it will move in the closing direction. At this point the command cannot
be used again until complete closure.
COURTESY LIGHT /CH2 RADIO OUTPUT
Binding posts "9 ","10 " are linked to a C-NO relay; this can be activated as follows.
• Jumper J5 in position 1:
the contact is closed by a timer and works as a "courtesy light"
• Jumper J5 in position 2:
the contact works as a second radio channel.
Binding posts "9 ","10" only give a potential free contact; this means that the courtesy light
will have to be powered by an external circuit and the contact used as a simple switch.
This device allows the propulsion unit to work during blackouts.
17