Attach the valve adapter to the valve
and turn to secure.
If you are using an RAV adapter, also
attach the extension supplied to the
valve tappet.
Use the screw and nut supplied for
additional fastening of RA and RAV
adapters.
Once the batteries have been inser ted, the motor
reverses; meanwhile, "InS" and the activity symbol (
are displayed. As soon as "InS" is displayed without the
activity symbol (
be mounted. This is followed by an adapter run ("AdA") to
adapt the thermostat to the valve.
Attach the radiator thermostat to the valve.
Tighten the union nut.
Press the boost button when "InS" is displayed.
The actuator performs an adapter run. "AdA" and the
activity symbol (
operation is not possible.
If the adapter run has been initiated prior to mounting or if
an error message (F1, F2, F3) is displayed, press the Boost
button; the motor reverses to the "InS" position.
If the MAX! Radiator Thermostat has not been taught-in
on the MAX! Cube, the device automatically switches to
manual operation (Manu).
Teach-in mode can be activated even whilst "InS"
is still displayed.
), the electronic radiator thermostat can