CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the
correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do
not move or transport gas cylinders with the protection cap removed. Do not allow the electrode,
electrode holder, work clamp or any other electrically live part to touch a gas cylinder. Gas cylinders
must be located away from areas where they may be subjected to physical damage or the welding
process including sparks and heat sources.

Installation and Operator Instructions

Read this entire section before installation or operation
of the machine.
Product Description
The PW345M C is a complete semiautomatic multi-
process DC arc welding machine offering CV and CC
DC welding. It is rated for 350Amps at 35% and
300amps at 60% duty cycle. The standard machine is
equipped to weld CC-Stick, CC-GTAW, CV-
FCAW,synergic and non-synergic CV-GMAW /
synergicGMAW-P processes. The digital microcomputer
based control system allows easy and accurate
adjustment of weld parameters through the multi-
process panel located on the front of the machine. The
PW345M C, is equipped according to the choosen
version with a 3-pin connector to allow operation of a
push-pull gun for feeding aluminum wires.
It is available with:
230 VAC/ 3.5 amp auxiliary power for water cooler.
For a quick and easy handling within the welding area,it
is factory mounted on a built-in undercarriage equipped
with a platform for a gas cylinder.
Location and Environment
This machine will operate in harsh environments.
However, it is important that simple preventative
measures are followed to assure long life and reliable
operation.
Do not place or operate this machine on a surface
with an incline greater than 7° from horizontal.
Do not use this machine for pipe thawing.
This machine must be located where there is free
circulation of clean air without restrictions for air
movement to and from the air vents. Do not cover
the machine with paper, cloth or rags when
switched on.
Dirt and dust that can be drawn into the machine
should be kept to a minimum.
This machine has a protection rating of IP23. It can
be used in moderate raining conditions without
causing any danger for users' safety.
Locate the machine away from radio controlled
machinery. Normal operation may adversely affect
the operation of nearby radio controlled machinery,
which may result in injury or equipment damage.
Read the section on electromagnetic compatibility in
this manual.
Do not operate in areas with an ambient
temperature greater than 40°C.
Only operate with the right door of the machine
closed.
Only use 15kg-coils, type 300 with this machine.
Input Supply Connection
Check the input voltage, phase, and frequency supplied
to this machine before turning it on. The allowable input
voltage is indicated in the technical specification section
of this manual and on the rating plate of the machine.
Verify the connection of grounding wires from the
machine to the input source. The frame of this machine
must be grounded. A ground terminal located on the
base of the generator is provided for this purpose.
This machine is factory 3ph-400V connected. To
connect it in 3ph-230V, remove the left case panel of the
machine to have access to the input reconnect panel.
Modify the connections according to the connection
diagram located on the inside of the case side.
Gas Connection
Once a gas cylinder has been securely installed on the
machine, connect the gas hose of the input cable to the
gas cylinder using a flow regulator.
Controls on the Case Front
A.
Front Panel: See description below.
B.
Status light: A two color light that indicates system
errors. Normal operation is a steady green light.
C. MSP3 Panel: See description below.
D. Euroconnector.
E.
Push Pull Receptacle: Following version
F.
ON/OFF Switch: It controls the input power to the
machine. Be sure the power source is connected to
the mains supply before turning power on ("I").
A-2