A. Non Synergic Welding Mode (CV Mode).
In this NON SYNERGIC (CV Mode) the presetting of the welding parameters (WFS and Voltage) are independent from
each others.
a. BEFORE WELDING :
Display of the Welding Wire
Feed Speed (WFS)
Presetting of the Welding Wire
Feed Speed (WFS)
b. DURING WELDING :
These actual values are displayed for 5 seconds after the end of the weld.
Display of the Actual
Welding Current
Setting of the
Welding Wire Feed
Speed (WFS)
In meters per
minute
In Amps
Display of the
Welding Voltage
Presetting of the
Welding Voltage
Display of the Actual
Welding Voltage
In Volts
In Volts
Setting of the
Welding Voltage