Keep button PROG
pushed
KNOB 1 :
Turn Right ( ) or Left ( )
Mode "NON SYNERGIC"
All memories are
"Free"
Mode "RECALL
MEMORY"
Steel 80/20
Stainless 98/2
Metal cored 98/2
Flux cored 80/20
Flux cored CO2
Al. / Mg 100% arg
Al. Si 100% arg
FLOW CHART "PROG" Menu
Release button PROG to access the
NON SYNERGIC Welding mode.
At least, One
memory is "Used"
Release button PROG to access the
RECALL MEMORY Welding mode.
KNOB 2 :
Turn Right( ) or Left ( )
Choose wire diameter (mm)
0.8 ; 1.0 or 1.2
0.8 ; 1.0 or 1.2
1.2 or 1.6
1.2 or 1.6
1.2 or 1.6
1.2 or 1.6
1.2 or 1.6
Release button PROG to
access the chosen
SYNERGIC Welding
mode.
11