10.1 - OIL CHANGE

• Check oil level periodically.
• Oil must be changed after the first 20 hours of operation of the machine. Subsequent oil
changes must be carried out every 150 hours of machine operation.
• In any case it is advisable to change the oil at least once a year.
• Used oil must be collected in containers and disposed of in special centres according to
current standards. It absolutely should not be discarded into the environment.
• Oil type: SAE 15W40 Mineral.
• Oil capacity: 0,33 liter.

10.2 - INLET FILTER

Before using the machine it is IMPORTANT to make sure that the filter is clean. Wash the filter
under a water tap or blow it with air to remove completely all dirt particles.
Remember that a well-cleaned filter means good performance and long life for your machine.
Remove filter from water inlet.

10.3 - REPLACEMENT OF HIGH PRESSURE NOZZLE

Periodically it is necessary to replace the high pressure nozzle as this is a component subject
to normal wear during use. This wear can generally be noticed by a decrease of the working
pressure. Contact your dealer if you wish to purchase a new nozzle.
Blow the filter with air.