5.4 - USE OF CORDS
If an extension cord is used, make sure that plug and receptacle are of a water-tight type. In
any case they must be raised from the ground in order to avoid possible contact with water.
WARNING
USE OF INADEQUATE
EXTENSION CORDS
MAY CAUSE SAFETY
Use only extension cables with the same number of conductors as those of the machine cable,
including the earthing cable, and with a suitable plug/socket for the cable used.
Only use extension cords for outdoor use. Said type of cable is marked "Suitable for outdoor
use." Store inside when not in use.
Do not use damaged extension cords. Cables should not be located near sources of heat or
sharp edges. Always disconnect the plug from the socket before removing the extension cord
from the product. Do not pull the cable to pull the plug out of the outlet. Do not touch the plug
or connections with wet hands.

5.5 - START-UP

- Before starting up and using the machine, make sure that it is positioned on the ground or
leaning against a stable support and that the resting surface is level or with a minimum slope.
- It is ESSENTIAL to ensure that the suction filter is clean before use. (see maintenance chap-
ter – 10.2 inlet filter).
1- Open water supply
2- Set the pressure to zero by turning the knob anti-clockwise.
3- Switch on the unit.
4- Hold the gun in the open position for a few seconds to allow the air to escape from hoses.
5- At this point adjust the machine to your pressure requirements and you are ready to enjoy
your work.
Attention! The water pressure at the outlet of the lance generates a force on itself;
therefore, grip the lance with both hands and with a secure grip.
- Switch off the machine when work is completed.
- Open the gun to release pressure still in the hose.
HAZARDS
SELECTION TABLE
Extension cord
Voltage
length
TURBO 8/70 - 11/50 - 15 - 19 - 21
220÷240
Up to 20 m
220÷240
From 20 to 50 m
100÷115
Up to 20 m
100÷115
From 20 to 50 m
TURBO 8/90 - TURBO 11/70 - TURBO 10/100
220÷240
Up to 20 m
220÷240
From 20 to 50 m
11
Cord section
mm
2
1,5
2,5
2,5
4
2,5
4