Herunterladen Inhalt Inhalt Diese Seite drucken

WimTec PROOF S6 Montage- Und Bedienungsanleitung Seite 21

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PROOF S6
Configuring the programs & functions
DIP switches:
Program activation – DIP switches 1 and 2:
Program
Semi automatic mode
Fully automatic mode
Manual mode
Function activation – DIP switches 3–6:
DIP switch
Function
3
Shut-off delay ON = 5 s / OFF = 2 s
4
Warm water rinse
5
Not allocated
6
Stagnation rinse
Preset program.
1)
Einstellregler:
D.
Range control
to detect user interaction
Sensor range preset to 50 cm
(configurable from 15 cm to
50 cm).
Sets the infrared sensor range
from 15 cm – 50 cm.
Automatic range adjustment
within the preset maximum
range.
DIP switch 1
OFF
1)
ON
OFF
E.
Time control
set to safety flow arrest after
10 min (configurable from
10 s to 10 min).
self-closing program mode:
10 s to 60 s.
After the configured maximum
flow time has elapsed, the
water stops automatically to
prevent unintentional conti-
nuous activation.
DIP switch 2
Description
ON
Page 29
ON
Page 30
OFF
Page 31
Factory setting
OFF
ON
-
OFF
F.
Interval control
for stagnation rinse
(configurable from 3 h to 48 h).
If the fitting has not been
used for the set period, the
device will automatically
perform a 10 s rinse to flush
stagnant water from the
pipes.
WimTec PROOF S6
Shower control
EN
Description
Page 32
-
Page 34
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis