Herunterladen Inhalt Inhalt Diese Seite drucken

Chamberlain MotorLift HC600 Mechanische Installation Seite 10

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
SAFETY MEASURES
THE WING GATE OPENER SHOULD ALWAYS BE OPERATED IN
CONJUNCTION WITH FLASHING LIGHTS AND PHOTOELECTRIC
BARRIERS FOR ADDED SAFETY.
In any case, take care to comply with the relevant standards and
regulations.
Should the force generated by the moving wing at its
closing edge exceed 400 N, additional safety features
(fotocells, contactstrips) must be fitted. Any safety features
fitted must comply with the appropriate standards.
FINAL REMARKS
Arrange the handover of the wing gate opener with your customer Make
sure that persons will operate the gate are familiar with its functions and
can operate them without problems. Have your customer practice
operating the gate until he is fully acquainted with all the following:
• Main switch.
• Rules of operation (e.g. do not drive through while the gate is still
opening).
• Additional safety features (photoelectric barrier, flashing lights, etc.).
• Switch to manual operation in case of power failure.
• Provide the customer with a full set of instructions. Inform him to keep
them in a safe place and read them when possible.
• Reference a checklist, so that you have a record of which functions
have been explained and of any points not dealt with.
TYPICAL CONFIGURATION OF A UNIT
1. Motor
2. Control board
3. photocell (active for closing), max. height 200 mm
First photocell.
4. photocell (active for opening), max. height 200 mm
Second photocell.
5. Flashing light (optional)
Important visual information on the movement of the gate.
6. Key-operated switch
Is mounted on the outside. The gate is opened by key or by entering a
number.
7. Contact strip (optional)
Safeguards the gate on being touched. Contact strips can be mounted
on the gate or on the pillars. If required, contact strips must be mounted
at a height of up to 2.5m.
8. photocell (active for opening/closing), max. height 200 mm
(optional)
TECHNICAL DATA
Model
Mains supply
Power consumption
Nominal power
Force max.
Nominal load
Capacitor
Temperature
Frequency Cycles/hr
Weight 1 Motor
Protection class
Max. door width
Max. door weight
ACCESSORIES
Model 84330EML
1-channel transmitter, 433.92MHz, with
Rolling Code
Model 84333EML
3-channel transmitter, 433.92MHz, with
Rolling Code
Model 84335EML
3-channel mini transmitter, 433.92MHz, with
Rolling Code
Model 8747EML
Keypad, 433.92MHz, with Rolling code
Model 760EML
Key switch
Model 34EML
2-Function Keyswitch, flush mount
Model 41EML
2-Function Keyswitch, surface mount
Model 771EML
Infrared barrier
Model ANT4X-EML
Antenna
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models HC600 Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives .........................................2006/95/EEC, 2004/108/EEC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener, when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
Harry Naumann
Manager, Regulatory Affairs
Chamberlain GmbH
D-66793 Saarwellingen
October, 2009
The control board complies with the latest EU
guidelines. One of these guidelines specifies that the closing
forces at the gate edge must not exceed 400 N (40 kg) for the last
500 mm before the door is CLOSED. Above 500 mm, the
maximum force at the gate edge must not exceed 1400 N (140
kg). If this cannot be ensured, a contact strip must be mounted on
the gate at a height up to 2.5 m or on the pillar on the opposite
side (EN12453).
HC600
230V-240V/50
400W
250W
300Nm
1.1A
8μF
-20
O
to +55
O
3o%
approx. 9kg
IP44
3.0m
250kg
conforms to the above Directives and Standard
s.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis