Operating instructions
5

Electric Connection

(see Figure 10 to 21, page 98 to 103)
Electric connection:
Cable inlet:
Signal range
Setpoint w:
4 to 20 mA
0/4 to 20 mA
The plastic housing is metallize coated inside against high-frequency radiation. This shield is connected with the
female thread jacks on the back side (see figure 5).
Please note that one of them must at least be connected to ground.
Fig. 5
Ground plate
6

Pneumatic Connection

CAUTION
!
If the electric supply is connected, the pneumatic supply must only be connected following
assembly if the positioner is switched to the input level "P manual mode" (for the as supplied condi-
tions, see leaflet "Operation -- a concise overview").
NOTICE
Ensure that the air quality is suitable! Grease-free industrial air, particulates < 30 μm, pressure dew
point 20 K below lowest ambient temperature.
The pneumatic connections are located on the right-hand side of the positioner (Figure 6).
54
Screw terminals 2.5 mm
M20 x 1.5
With 2-wire connection
With 3-wire or 4-wire connection
Power supply U
: 18 to 30 V
H
2
Shield
SIPART PS2
A5E00074600-05