Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning The Unit (Shutting Down); Cleaning The Unit From The Outside; Suction Filter Hc 35 G - WAGNER HC 45 G-SSP Betriebsanleitung

Airless hochdruck-spritzgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Interruption of work
3. Switch off the gasoline engine.
4. Pull the trigger guard of the spray gun in order to re-
lease the pressure from the high-pressure hose and
spray gun.
5. Secure the spray gun, refer to the operating manual of
the spray gun.
6. If a standard tip is to be cleaned, see page 53, point
13.2.
If a non-standard tip is installed, proceed according to
the relevant operating manual.
7. Leave the suction tube immersed in the coating mate-
rial or immerse it in the corresponding cleaning agent.
If fast-drying or two-component coa-
ting material is used, ensure that the
unit is rinsed with a suitable cleaning
agent within the processing time.
Attention
8.
Cleaning the unit
(shutting down)
A clean state is the best method of ensuring operation
without problems. After you have finished spraying, cle-
an the unit. Under no circumstances may any remaining
coating material dry and harden in the unit.
The cleaning agent used for cleaning (only with an igniti-
on point above 21 °C) must be suitable for the coating
material used.
• Secure the spray gun, refer to the operating manual
of the spray gun.
Clean and remove tip.
For a standard tip, refer to page 53, point 13.2.
If a non-standard tip is installed, proceed according to
the relevant operating manual.
1. Pull retention pin and swivel material feed pump out
of coating material.
2. Pull the trigger guard of the spray gun in order to
pump the remaining coating material from the suction
tube, high-pressure hose and the spray gun into an
open container.
The container must be earthed in case of
coating materials which contain solvents.
Attention
Caution! Do not pump or spray into a
container with a small opening (bung-
hole)!
Refer to the safety regulations.
Danger
40
g
3. Pull retention pin and swivel material feed pump to a
container with suitable cleaning agent.
4. Turn the relief valve knob three revolutions to the left
(k Circulation).
5. Pump a suitable cleaning agent in the circuit for a few
minutes.
6. Turn relief valve knob to the right (p spray).
7. Pump the remaining cleaning agent into an open con-
tainer until the unit is empty.
8. Turn the relief valve knob three revolutions to the left
(k Circulation).
9. Close ball valve on material feed pump – lever position
horizontal.
10.Switch off the gasoline engine.

8.1 Cleaning the unit from the outside

Switch off the gasoline engine and let it
cool down.
Danger
Danger of short-circuits caused by water
ingressing into the electrical equipment of
the gasoline engine.
Never spray down the unit with high-pres-
sure or high-pressure steam cleaners.
Danger
Wipe the unit off with a cloth soaked in a suitable clea-
ning agent.
8.2 Suction filter with HC 35 G
A clean suction filter always guarantees
i
maximum feed quantity, constant spraying
pressure and problem-free functioning
of the unit.
– Screw off the filter (fig. 14) from suction pipe.
– Clean or replace the filter.
Carry out cleaning with a hard brush and an appro-
priate cleaning agent.

Cleaning the unit (shutting down)

HC 35 G • HC 45 G • HC 55 G

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hc 55 gHc 55 g-sspHc 45 gHc 35 g

Inhaltsverzeichnis