DMX Operation
• Push the FUNCTION (11) button 5x as described above and set the DMX start address.
The DMX start address can be set from 1 to 510 and defines the first channel to which the device reacts.
• You can now control the device from your DMX controller. For the functions of the individual channels, see the
following table.
DMX channel Value
1
0-255
2
0-255
3
0-127
128-255
c) Operation as a fog machine
Operation at the Device
Timer Operation
• Push the FUNCTION (11) button to make several pre-settings for timer operation:
- Push 1x to set the pause time of the working interval with the
- Push 2x to set the emission time of the working interval with the
- Push 3x to set the fog volume with the
- Push 4x: this setting is only available in hazer operation. No settings are usually required here in fog operation.
- Push 5x to set the DMX starting address for DMX operation as described below with the
buttons.
• The TIMER (16) button starts timer operation with the above settings.
• The settings can be adjusted by pushing the FUNCTION (11) button and changing the values with the
and
(14) buttons as well during timer operation.
• To interrupt timer operation, push the
Manual Operation
• Push the VOLUME PUMP/FAN (17) button to operate the device manually (without a timer).
• The device will start fog operation.
• Push the FUNCTION (11) button to change the FOG (fog volume) parameter.
• Change the fog volume with the
• To interrupt manual operation, push the
28
Function
Fog amount 0-100 %
Fan speed 1-100 %
Hazer operation on
Hazer operation off
(13) and
(15) button.
(13) and
(14) buttons.
(15) button.
(13) and
(14) buttons.
(13) and
(14) buttons.
(14) buttons.
(13) and
(14)
(13)