Door delay alarm
9
0
9
1 to 999
Be sure to respect the alarm duration prescribed by the law. In Germany, the
alarm may not sound for longer than 3 minutes. If you own an alarm system, it
is your responsibility to ensure that this time is not exceeded.
The following parameters are set at the factory:
Parameter
Explanation
8900
Single user mode
401
Output 1 switches for 1 second
501
Output 2 switches for 1 second
601
Output 3 switches for 1 second
70
After 10 wrong code entries the keypad is disabled for 30 seconds
800
Door activity alarm is deactivated
811
Opening sound is deactivated
820
User code entry must be confirmed with the # key (only when swit-
ched to multi-user mode)
821
User code can be entered without using the # key (as delivered or
when in single user mode)
831
Key tones are activated
90
Door delay alarm is deactivated
58
#
The door delay alarm is switched off.
#
Once the connection between the terminal (-) GND
ground and the terminal "DOOR SENS" is opened and
the programmed time (1 to 999 seconds) has expired, the
alarm will sound until the connection between the two
terminals is restored.