Herunterladen Inhalt Inhalt Diese Seite drucken

Renkforce 751074 Bedienungsanleitung Seite 45

Digitales codeschloss mit hintergrundbeleuchtung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TAMPER
Sabotage contact for a 24 h NC-alarm loop in alarm installations
(max. 24 V, 50 mA, Current-free)
DOOR BELL
Current free contact for doorbell (max. 30 V (AC/DC), 1 A
12-24 VAC/DC
Power supply connection (12 - 24 V (AC or DC).
Be sure to use the correct polarity,when connecting DC voltages.
EG IN
Door opener button contact
OUTPUT 1
Schaltausgang 1
N.C.: Opener contact (N.C./COM)
COM: combinated Connection
N.O.: Closing contact (N.C./COM)
O/P 3
Output 3, NPN switched output max. 24 V/DC, 100 mA;
witches to minus potential (-). Suitable for control purposes (AUX)
KEY ACT
NPN switch output for keypad or Alarm
KEY: Output switches with pressing buttons for 10 s of GND
AL: Alarm output for unauthorized entry (DOOR SENSE-Evaluation)
DOOR SENSE
Door contact (for magnetic switches, if this contact is not used
then a jumper to the minus terminal (- GND) must be installed)
(-) GND
(-) Ground contact (GND)
DU OUT
"DURESS" coercion contact - this contact switches to ground
potential if an incorrect code was entered 10 times during pro-
gramming (71).
O/P 1 INHIB.
Output 1 access control.
INT LOCK
NPN switched output that switches to the minus potential (-) for
5 seconds when a correct user code is entered. In a two-door sys-
tem this can be used to avoid both doors being opened at the same
time (two code locks required)
OUTPUT 2
Switching output 2
N.C.: Opener contact (N.C./COM)
COM: combinated Connection
N.O.: Closing contact (N.C./COM)
45

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis