Herunterladen Inhalt Inhalt Diese Seite drucken

Name Of Parts; Units Installation - Hitachi P-AP160NA1 Installations- Und Betriebshandbuch

4 - way cassette
Vorschau ausblenden Andere Handbücher für P-AP160NA1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39

Name of parts

2 NAME OF PARTS
RCI

 

3 UNITS INSTALLATION

D A N G E R
Check to ensure that the accessories are packed with the
indoor unit.
Do not install the indoor units outdoors. If installed out-
doors, an electric hazard or electric leakage will occur.
Consider the air distribution from each indoor unit to the
space of the room, and select a suitable location so that
uniform air temperature in the room can be obtained. It is
recommended that the indoor units be installed 2.3 to 3
meters from the floor level. If the unit is installed higher
than 3 meters, it is also recommended that a fan be utili-
sed to obtain uniform air temperature in the room.
Avoid obstacles which may hamper the air intake or the
air discharge flow.
Pay attention to the following points when the indoor
units are installed in a hospital or other places where the-
re are electronic waves from medical equipment, etc.
Do not install the indoor units where electromagnetic
wave is directly radiated to the electrical box, remote con-
trol cable or remote control switch.
Prepare a steel box and install the remote control switch
in it. Prepare a steel conduit tube and wire the remote
control cable in it. Then connect the ground wire with the
box and tube.
Install a noise filter when the power supply emits harmful
noises.
7
PMML0280A rev.1 - 09/2014
No.
1
2
3
4
5
6
7
8
9
Liquid refrigerant connection
10
11
Motor for drain discharge mechanism
12
13
14
P-AP160NAE (with motion sensor)
15
16
17
18
19
This unit is exclusive non electrical heater type indoor
unit. It is prohibited to install a electrical heater in the
field.
Do not put any foreign material into the indoor unit and
check to ensure that none exist in the indoor unit before
the installation and test running. Otherwise a fire or failu-
re, etc., may occur.
C A U T I O N
Do not install the indoor units in a flammable environment to
avoid a fire or an explosion.
Check to ensure that the ceiling slab is strong enough. If not
strong enough, the indoor unit may fall down on you.
Do not install the indoor units, outdoor unit, remote control
switch and cable within approximately 3 meters of strong elec-
tromagnetic wave radiators such as medical equipment.
Do not install the indoor units in a machinery shop or kitchen
where vapor from oil or mist flows to the indoor units. The oil
will deposit on the heat exchanger, thereby reducing the indo-
or unit performance, and may deform. In the worst case, the
oil damages the plastic parts of the indoor unit.
To avoid any corrosive action to the heat exchangers, do not
install the indoor units in an acid or alkaline environment.
When lifting or moving the indoor unit, use appropriate slings
to avoid damage and be careful not to damage the insulation
material on units surface.
Part Name
Fan
Fan motor
Heat exchanger
Distributor
Strainer
Expansion valve
Electric control box
Gas refrigerant connection
Drain pipe connection
Float switch
Drain pan
Panel P-AP160NA1
Air inlet grille
Air filter
Air outlet
Air inlet
Cover for corner pocket

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

P-ap160naeRci-1.0-fsn3ekRci-6.0fsn3ek

Inhaltsverzeichnis