Place the device at a height of around 2 metres, in the darkest part of the room, far away from any windows. This will
allow the device to eliminate the insects inside the house and will avoid attracting those which are outside. The wall
must not present any obstructions which could make it difficult to remove the sticking paper or clean the device. Make
sure that the wall where the device is to be mounted is solid and that no electric cables pass through it.
1.
Using a drill with a 5 mm bit, make 2 holes in the wall and insert the screw anchors (B) supplied in the holes (fig. 1).
2.
Fix the bracket (C) to the wall placing the 2 screws (A) in the holes in the upper part (fig. 1).
3.
Open the device cover and using a pair of scissors cut just enough off the cable passage to slide in the conductor
protection sheath.
4.
Make the electrical connections: for the passing through of the cables you can use the existing opening (D) or the
optional one, after having removed the circular closure (E)
5.
Screw the bulb into the bulb holder (F) (fig. 2).
6.
Insert the lamp in the protective cage, putting the bulb holder into place (fig. 3).
7 .
Close the cover by means of the 4 screws (G) (fig. 4).
8.
Place the sticking paper (H) into position; remove the protective film from the paper, and place it centrally on the
cover and slide it into the fixing grippers (I) (fig. 5).
9.
Mount the cover (with the sticking paper) into the bracket, taking care to slide the upper rim of the cover into the
upper lip of the bracket (fig. 6).

CLEANING AND MAINTENANCE

Before carrying out any cleaning or maintenance operation on the machine make sure that
the contacts on the bipolar switch are open.
A general cleaning of the appliance must be done e ach time that the glued paper is changed. For this operation you
must use a cleaning substance suitable to be used within food-processing environments. All maintenance operations
must be carried out after having disconnected the appliance from the power supply.
To ensure the best operation of the device, replace the bulb once a year.
The sticking paper must be replaced at least once a month or more often if used in particularly dirty places or where
there are lots of insects. If the sticking paper gets stuck to the lamp, clean it with a soft cloth soaked in non-corrosive
detergent, taking care not to scratch the lamp. The rejected or used sticking papers must be disposed off in conformity
with the regulations in force in the place the device is installed.

TECHNICAL ASSISTANCE

For any queries regarding this device, please contact your supplier. In case of breakdown or malfunction, switch the
device off and take it or send it to the nearest technical service centre.
Only authorised technical service centres which use original spare parts can carry out repairs.

TECHNICAL DATA

Model
Voltage
Consumption
UV-A Bulb
Production material
Range
Weight
Size
Sticking paper size
505399-400 en de fr ma 2012
398
220-240 V ~ 50-60 Hz
20 W
1 x 20 W
Steel Inox AISI 304
10 ~ 12 m
2.3 kg
400 x 170 x 270 mm
345 x 200 mm
399
220-240 V ~ 50-60 Hz
20 W
1 x 20 W
Polystyrene + self-extinguishing polystyrene
10 ~ 12 m
0.8 kg
400 x 170 x 270 mm
345 x 200 mm