OPERATION
IMPORTANT !!!
Before starting any shredding operation and before any material is introduced into the Cyclone the
following points must be carefully checked:
1. When the "START" button is pressed the Cyclone main motor starts and the
plastic bag must be inflated by the turbine airflow.
2. The Cyclone must shut itself off after approximately 30-40 seconds ( in case
adjust the "ALARM C" knob located in the electrical panel board, see Electrical
Set-up and Tuning section attached to this manual).
26 di 55
GB