Starting up

3. Starting up
3.1 Start-up check
3.2

Cancelling an error message

3.3

Calibrating the FeVac Two

8
When all connections have been made, first switch on all FeVac
FeVac Two unit using the power switch at the rear. As soon as the systems are switched on, FeVac One
starts testing the FeVac Two systems.
As each FeVac Two is checked by FeVac One , the display shows the address (XX) and then OK if no
errors are discovered. The keys of the FeVac Two do not work when it is being checked.
**** FEVAC 2 ****
SYSTEM XX :
OK
If the system check is completed and an error was detected, the following display appears:
**** FEVAC 2 ****
SYSTEM XX : ERROR
The Error LED lights up at the same time and the appropriate error message is sent to the FeVac One .
**** FEVAC 2 ****
SYSTEM XX : ERROR
Press the Reset key to cancel an FeVac Two error message. The next time the FeVac One checks the FeVac
Two, the same error message is sent to the FeVac Two unless the error in question has been corrected.
When calibration is initiated by the FeVac One (it cannot be initiated by the FeVac Two), the following
display appears on the appropriate FeVac Two.
CALIBRATING
PLEASE WAIT
Two units and then switch on the
®