Herunterladen Inhalt Inhalt Diese Seite drucken

Malfunctions During Operation - HEYLO KT 20 Betriebsanleitung

Kondensationstrockner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

17.2

Malfunctions during operation

Malfunction
The device is not running No or incorrect power supply
No condensate forms
although the fan is run-
ning
The device is noisy and
vibrates, condensate
escapes
The device warms up,
becomes noisy and de-
humidifies poorly
Tab. 10:
Table of malfunctions
KT 20
Possible cause
Target humidity is set too high (with built-
in hygrostat)
Filter is clogged
Fault on the evaporator
Pump is defective
Pump sump is clogged
Device is not level and upright
Disturbed air circulation
Remedy
Check the power cable and the mains
connection.
Check the setting of the target humidity
Check the filters, replace them if neces-
sary
Contact the HEYLO technical staff
Contact the HEYLO technical staff
See Cleaning the pump sump
Check the operating conditions, particu-
larly the installation site
Ensure that the air can circulate freely.
Clean the air slits in the protective cover.
Check the air filter.