NOTICE
c) Let the cleaned components dry.
d) Mount the safety covers in the same way as they were installed at the factory.
 You have now cleaned the evaporator.
Inspecting the electrical system
DANGER
a) Check all the device's electrical components visibly for signs of external damage, loose contacts and con-
tamination. Remove the safety cover in order to inspect the internal wiring. Remove any external contami-
nation with a lint-free cloth and replace any defective or damaged components.
b) If used commercially in Germany: Conduct an annual DGUVV3 examination in accordance with the
Berufsgenossenschaft (trade association) requirements and keep a record of it.
 The inspection of the device's electrical system is now complete.
18.2

Cleaning the pump sump

Depending on the way the device is used, deposits may form in the pump sump after a while. To clean the
pump sump, proceed as follows:
KT 20
Remove any hard or caked deposits with a special cleaner
With hard or caked deposits, use the cooling coil cleaner from HEYLO. Ensure that
you follow the cleaning instructions on the product.
Touching electrically live parts can be fatal.
Improper or inadequate inspection and maintenance can lead to device components
becoming live during operation due to a defect.
a) Inspection of the electrical system should only be conducted by a qualified elec-
trician.
b) After the work has been completed, install and test all the safety devices as in-
tended.