2. Ensure that the mains socket is
sufficiently protected (see
Technische Daten/Technical Da-
ta).
3. The power socket to which the
device is connected must be
equipped with a RC circuit break-
er. This is particularly important for
operation in humid rooms and on
construction sites.
4. Make sure that the mains socket is
earthed and matches the power
plug of the device.
5. Connect the power plug into the
mains socket.
8 Device operation and
control
Prior to switching on
1. Make sure that the device is not
standing on a wet ground and en-
sure that it is in an upright and
stable position.
2. Make sure that the condensate
can drain off properly.
3. If necessary, record the readings
of the operating hours counter and
the power meter.
NOTICE! Before starting the device
for the first time, after transport
and after prolonged storage, leave
the device in its final position for
approx. 15 minutes before switch-
ing it on.
Switching on device and
continuous operation
1. Set the device switch to position
[I].
 The green indicator is lit, in-
dicating that the compressor
in
is running.
 The device is set to continu-
ous mode and runs until the
automatic defrost function is
triggered (yellow indicator lit).
In continuous mode, conden-
sate is automatically pumped
off.
Pumping off condensate (before
moving device to a different
location)
✓ The device must not be in defrost
mode (yellow indicator must be
off).
1. Set the device switch to position
[II].
 The condensate pump starts
to pump the condensate
through the drain hose into
the drain or the on-site drain /
collecting vessel.
2. As soon as there is no condensate
left in the tank, quickly set the
switch to position [0], to prevent
the pump from running dry.
Operation with external hygrostat
✓ A hygrostat is connected to the
port on the device.
1. Set the hygrostat to the desired
target humidity.
2. Set the device switch to position
[I].
 The device starts in dehu-
midifying mode.
 The device switches off automat-
ically as soon as the set target
humidity is reached. The device
remains however in ready mode.