Fig. 9:
Components, internal
1 Evaporator
3 Compressor
5 Internal condensate hose
7 Opened housing
9 Filter holder with filter
The scope of supply includes:
– Condensation dryer.
– Condensate drain hose.
– Filter mat.
– Operating manual.
The following are available as accessories:
– Hygrostat controller.
How it functions
The device dehumidifies the air in the room. If the device is switched on at the device switch on the control pan-
el, it will run in continuous operating mode. The fan draws the humid room in air via the air inlet opening. The air
flows along the evaporator, where it cools down. At the evaporator, the moisture from the air accumulates in the
form of condensate. After the room air has been led past the evaporator, it is heated in the condenser and trans-
ferred back into the room at the air outlet as dried and heated air. The dried, warm air can begin absorbing
moisture again in the room.
The condensate is collected in a tray under the evaporator and led through the device's internal condensate
hose to the condensate pump. The condensate pump is controlled by a float switch. When the condensate in
the condensate tank reaches the float switch, the pump will start and convey the condensate into the drain or
KT 20
2 Terminal box
4 Fan
6 Condensate container with float switch
8 Condensate pump
10 Condensate tray
EN
Product description | 14
53 / 81