14 | Product description
into the collecting vessel below via the connected condensate drain hose. The pump will stop as soon as the
float switch is no longer assigned.
Automatic de-icing
Ice forms on the evaporator after longer operating time (in continuous operating mode). A temperature sensor
reports the frost temperature to the device control system and automatic defrosting is started. The evaporator is
heated during the defrosting process. Large amounts of condensate accumulate during automatic defrosting. As
soon as the evaporator is free of ice, the device starts the dehumidifying operation again.
NOTICE
Pumping out the condensate
The condensate must be drained completely before transport or storage when the device is no longer in use or
if it is to be operated at a different location or if it is to be shut down for a longer period of time. In such a situa-
tion, the condensate pump can be started manually with the device switch.
Operation with a hygrostat
An external hygrostat (Heylo Art. No. 1110552) can be connected to the device. The target humidity can be set
and regulated with a hygrostat. For this purpose, the external hygrostat is connected to the connection socket.
See also
 Intended use
[
54]
14.2.1

Intended use

The device is intended solely for commercial use in dehumidifying air in closed interior rooms at atmospheric
pressure.
Intended use also includes observance of the operating conditions (see Operating conditions
Any other use or any application transcending the specified use is considered improper use. Improper use will
result in all warranty claims becoming void.
See also
 Technical details
[
74]
54 / 81
The amount of ice
The amount of condensate and ice that arises will depend very much on the ambient
conditions (air temperature and air humidity) in which it is used. The air humidity in
the room can be measured regularly with a thermo-hygrometer in order to measure
the moisture extracted by the device.