Herunterladen Diese Seite drucken

GEV CVB 086210 Anleitung Seite 4

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
1- and 2-family house video doorphone set CVB
Operating elements
Connection elements
Indoor monitor (Fig. A)
Indoor monitor (Fig. C)
1 Screen
1 To outdoor monitor <> 1
2 LED status indicator
2 To outdoor monitor <> 2
3 Loudspeaker
3 To outdoor monitor <> 3
4 Bell tone selection/OFF
4 To outdoor monitor <> 4
5 Bell tone volume
5 Electromagnetic door opener
6 Brightness
connection
7 Contrast
6 Supply voltage socket
8 Microphone
Outdoor monitor(Fig. D)
9 Door open button
10 Monitoring
1 To indoor monitor <> 1
1
11 Talk button
2 To indoor monitor <> 2
3 To indoor monitor <> 3
Outdoor monitor (Fig. B)
4 To indoor monitor <> 4
1 Microphone
1 To indoor monitor <> 1
2
2 Infrared LED
2 To indoor monitor <> 2
3 Camera
3 To indoor monitor <> 3
4 Loudspeaker
4 To indoor monitor <> 4
5 Ringer switch/nameplate
6 Light sensor
7 Cover
Power pack (Fig. E)
1 Connector
Please read these instructions carefully and keep for future reference.
By purchasing this item, you have chosen a high-quality GEV product.
Please read these operating instructions carefully to ensure correct
operation. Keep these instructions in a safe place so that you can refer
back to them if necessary.
Safety instructions
Under no circumstances does the warranty cover damage
resulting from failure to observe theseinstructions. Nor do we
accept liability for any indirect damage. Similarly, we can accept
no liability for any material damage or bodily injury caused by
mishandling or failure to observe the safety instructions. In these cases,
no warranty or guarantee claim may be made. In addition, for safety and
compliance reasons, you are not authorised to dismantle or alter the device
in any way.
Door opener
An electromagnetic door opener can be connected via the indoor monitor to
the video doorphone set CVB. It receives its supply voltage from the video
doorphone set CVB.
Please observe the technical data.
Installation
If in any doubt, rather than mounting, connecting or installing the equipment
yourself, contact a qualifi ed technician.
The outdoor unit is designed for surface mounting. When deciding where to
install the outdoor monitor, choose a position that is well protected against
the elements, particularly rain. The camera (B3) should face upwards. Refer
to the information about the optimum camera position (Fig. F). Remove the
cover and undo the screws according to Fig. G. Carefully remove the
cover to write on the nameplate. Connect the doorphone set according to
Fig. J. Install the outdoor monitor according to Fig. H and fi t the seal so
that the open end faces downwards. Install the indoor monitor according
to Fig. I.
Operation
Connect the E1 power pack plug to socket C6. The green LED A2 lights
up and the B5 nameplate on the outdoor monitor also lights up. The
device is now ready for use.
Use switch A4 on the indoor monitor to select the required bell tone
(1 to 3) or disable the bell tone (0 = OFF). If the bell tone is disabled,
the red LED A2 will light up. Use volume adjustment A5 to set the bell
tone volume independently of the general volume. The general volume
is preset.
If a visitor presses the ringer switch B5, the indoor monitor will ring. The
visitor can then be seen via the outside monitor by the person inside the
building. When using for the fi rst time, adjust the brightness and contrast
settings (A6/A7). Button A10 lights up when connection from the outdoor
to the indoor monitor is enabled. If no buttons are pressed, connection
will stop automatically after approx. 30 seconds. You can talk to the
visitor by pressing the talk button A11. Press the door open button A9 to
activate the (optional) door opener. Press button A10 or press talk button
A11 again to stop the connection. Connection also stops automatically
after approx. 60 seconds.
Outside monitoring
Press button A10 to monitor the outside area for 30 seconds.
EC compliance information
Using the device near electromagnetic high frequency fi elds such as radio
systems, microwaves or mobile phones, or high electrostatic discharge,
can interfere with device operation. Should you encounter problems,
switch the power supply off and on again to restore operation.
Recycling instructions
This device may not be disposed of with unsorted household
waste. Owners of old devices are required by law to dispose of
this device correctly. Contact your local town council for further
information.
4
Troubleshooting - practical advice
Fault
Cause
No bell tone +
• Is the power pack connected?
LED does not light up
• Is the power pack faulty?
• Faulty device?
No bell tone/signal +
• Indoor monitor cable to outdoor monitor
green LED lights up
incorrectly connected/faulty?
No bell tone +
• Is the bell tone volume set to 0?
red LED fl ashes
Technical information
Monitor
Type TFT 64 mm visible diagonal size
Camera lighting
min. 3 lux located at < 50 cm
Operating voltage
15 V DC
Indoor unit power consumption
Standby approx. 1.3 W
Operation approx. 7.5 W
Recommended cable
J-Y(ST)Y 4x2x0.8
Distance from indoor to outdoor monitor
max. 100 m
Operating voltage for door opener
12 V DC /max. 1A
Outdoor unit protection type
IP 44
Indoor unit protection type
IP 20
Outdoor monitor temperature range
-10°C to +45°C
Indoor unit temperature range
0 °C bis +35 °C
Measurements:
Indoor monitor
approx. W 115 x H 220 x D 32 mm
1-family house outdoor monitor
approx. W 110 x H 157 x D 36 mm
2-family house outdoor monitor
approx. W 110 x H 157 x D 36 mm
Power pack
Input voltage
100 V - 240 V AC, 50/60 Hz
Output voltage
15 V DC
Rated current
max. 1 A
Technical and design features may be subject to change.
Gutkes GmbH
Owiedenfeldstr. 2 a
Postfach 730 308
Fax: +49(0) 511 / 958 58 05
30559 Hannover
30552 Hannover
www.gev.de.
Germany
Germany
service@gev.de
Solution
• Connect plug-in power pack
• Check plug-in power pack
• Check the device
• Check the cable
• Set bell tone to 1, 2 or 3