Anleitung NLE 20 E_SPK7
Read these instructions carefully and
keep them in a safe place.
Layout (Fig. 1)
1
ON/OFF switch with air humidity adjuster
2
"W.F." LED for condensate collector full
3
"Power" LED
4
Air outlet grille
5
Handle
6
Front housing panel
7
Condensate container with water level indicator
8
Air inlet grille with air filter
9
Back housing panel
10 Connection for condensate drainage hose
11 Castor
12 Mains cable
Description of the control panel (Fig. 2)
W.F.: The "Condensate container full" indicator lights
up red whenever the condensate container is full.
RH 40%...RH 70%: The "Adjustable room humidity"
indicator lights up green as soon as the range has
been selected and the appliance is switched on.
Power: This lights up red as soon as the mains
voltage is present and then lights up green when the
appliance is switched on.
Pressure switch (A): For setting the functions
On/Off/Room humidity.
Technical data
Power supply:
Max. rated current consumption:
Starting current:
Max. power consumption:
Sound pressure level:
Dehumidifying capacity:
0.8 l/h (at a room temperature of 30°C and air
0.5 l/h (at a room temperature of 27°C and air
Operating range for humidity
Operating range for temperature:
Max. air flow volume:
Volume of condensate container:
18.09.2006
15:59 Uhr
Seite 7
Coolant:
Coolant quantity:
Appliance dimensions:
Appliance weight:
Features
Once the predefined room humidity has been
reached the integrated compressor in the appliance
switches off automatically. The fan continues running
so that the air humidity in the room can be
monitored. The compressor switches on again
automatically whenever the predefined air humidity in
the room is exceeded. The appliance then switches
off automatically when the condensate container is
full. Provision has also been made for the
condensate to be drained off permanently if required.
Operating principle
Evaporator
Humid
air
Condensed
water tank
230 V ~ 50 Hz
1.8 A
The dehumidifier controls the relative humidity of the
7.5 A
inlet air. The humid air condenses on the cooler
elements and is transferred to the water tank. The
400 W
dry air is heated a little on the condenser and
≤ 48 dB(A)
returned to the room.
Scope of use
humidity of 80%)
The dehumidifier is designed for private use only
humidity of 60%)
(e.g. for living rooms, bedrooms, bathrooms,
40-80%
storage areas, laundry rooms or cellars).
8 -32°C
Note:
180 m
3
70% air humidity is the upper limit with which the
5.3 liters
human body feels comfortable. If it is too warm for
GB
R134a
170 g
340 x 540 x 260 mm
15.5 kg
Condensor
Dry air
Compressor
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis